Selection Part Number Part Selection Description
1910PL06

1/4" O.D. FDA-grade vinyl body with 1/8" O.D. polyethylene inside tubing. 6, 12, 18, 24, 36, 48, and 60 in. lengths available. Ends in female luer connection. Includes 1/8" NPT connection to mount. Length and ceramic type can be customized. Complies with ASTM D4696-92(2000), Standard Guide for Pore-Liquid Sampling from the Vadose Zone.

1910PL12

1/4" O.D. FDA-grade vinyl body with 1/8" O.D. polyethylene inside tubing. 6, 12, 18, 24, 36, 48, and 60 in. lengths available. Ends in female luer connection. Includes 1/8" NPT connection to mount. Length and ceramic type can be customized. Complies with ASTM D4696-92(2000), Standard Guide for Pore-Liquid Sampling from the Vadose Zone.

1910PL18

1/4" O.D. FDA-grade vinyl body with 1/8" O.D. polyethylene inside tubing. 6, 12, 18, 24, 36, 48, and 60 in. lengths available. Ends in female luer connection. Includes 1/8" NPT connection to mount. Length and ceramic type can be customized. Complies with ASTM D4696-92(2000), Standard Guide for Pore-Liquid Sampling from the Vadose Zone.

1910PL24

1/4" O.D. FDA-grade vinyl body with 1/8" O.D. polyethylene inside tubing. 6, 12, 18, 24, 36, 48, and 60 in. lengths available. Ends in female luer connection. Includes 1/8" NPT connection to mount. Length and ceramic type can be customized. Complies with ASTM D4696-92(2000), Standard Guide for Pore-Liquid Sampling from the Vadose Zone.

 

1910PL36

1/4" O.D. FDA-grade vinyl body with 1/8" O.D. polyethylene inside tubing. 6, 12, 18, 24, 36, 48, and 60 in. lengths available. Ends in female luer connection. Includes 1/8" NPT connection to mount. Length and ceramic type can be customized. Complies with ASTM D4696-92(2000), Standard Guide for Pore-Liquid Sampling from the Vadose Zone.

1910PL48

1/4" O.D. FDA-grade vinyl body with 1/8" O.D. polyethylene inside tubing. 6, 12, 18, 24, 36, 48, and 60 in. lengths available. Ends in female luer connection. Includes 1/8" NPT connection to mount. Length and ceramic type can be customized. Complies with ASTM D4696-92(2000), Standard Guide for Pore-Liquid Sampling from the Vadose Zone.

1910LL12

1/4" O.D. FDA-grade vinyl body with 0.094" O.D. hypodermic-quality stainless steel inside tubing. 6, 12, 18, 24, 36, 48, and 60 in. lengths available. Ends in female luer connection. Length and ceramic type can be customized. Complies with ASTM D4696-92(2000), Standard Guide for Pore-Liquid Sampling from the Vadose Zone.​

1910LL24

1/4" O.D. FDA-grade vinyl body with 0.094" O.D. hypodermic-quality stainless steel inside tubing. 6, 12, 18, 24, 36, 48, and 60 in. lengths available. Ends in female luer connection. Length and ceramic type can be customized. Complies with ASTM D4696-92(2000), Standard Guide for Pore-Liquid Sampling from the Vadose Zone.​

1909L01

3/8" O.D. butyrate body with 1/8" O.D. polyethylene inside tubing. 1, 6, 12, 18, 24, 36, 48, and 60 in. lengths available.

1910LL36

1/4" O.D. FDA-grade vinyl body with 0.094" O.D. hypodermic-quality stainless steel inside tubing. 6, 12, 18, 24, 36, 48, and 60 in. lengths available. Ends in female luer connection. Length and ceramic type can be customized. Complies with ASTM D4696-92(2000), Standard Guide for Pore-Liquid Sampling from the Vadose Zone.​

1909L12

3/8" O.D. butyrate body with 1/8" O.D. polyethylene inside tubing. 1, 6, 12, 18, 24, 36, 48, and 60 in. lengths available. Ends in female luer connection. Length and ceramic type can be customized.  Complies with ASTM D4696-92(2000), Standard Guide for Pore-Liquid Sampling from the Vadose Zone.

1909L18

3/8" O.D. butyrate body with 1/8" O.D. polyethylene inside tubing. 1, 6, 12, 18, 24, 36, 48, and 60 in. lengths available. Ends in female luer connection. Length and ceramic type can be customized.  Complies with ASTM D4696-92(2000), Standard Guide for Pore-Liquid Sampling from the Vadose Zone.

 

1909L24

3/8" O.D. butyrate body with 1/8" O.D. polyethylene inside tubing. 1, 6, 12, 18, 24, 36, 48, and 60 in. lengths available. Ends in female luer connection. Length and ceramic type can be customized.  Complies with ASTM D4696-92(2000), Standard Guide for Pore-Liquid Sampling from the Vadose Zone.

1910LL48

1/4" O.D. FDA-grade vinyl body with 0.094" O.D. hypodermic-quality stainless steel inside tubing. 6, 12, 18, 24, 36, 48, and 60 in. lengths available. Ends in female luer connection. Length and ceramic type can be customized. Complies with ASTM D4696-92(2000), Standard Guide for Pore-Liquid Sampling from the Vadose Zone.​

1909L36

3/8" O.D. butyrate body with 1/8" O.D. polyethylene inside tubing. 1, 6, 12, 18, 24, 36, 48, and 60 in. lengths available. Ends in female luer connection. Length and ceramic type can be customized.  Complies with ASTM D4696-92(2000), Standard Guide for Pore-Liquid Sampling from the Vadose Zone.

1909L48

3/8" O.D. butyrate body with 1/8" O.D. polyethylene inside tubing. 1, 6, 12, 18, 24, 36, 48, and 60 in. lengths available. Ends in female luer connection. Length and ceramic type can be customized.  Complies with ASTM D4696-92(2000), Standard Guide for Pore-Liquid Sampling from the Vadose Zone.

1909L60

3/8" O.D. butyrate body with 1/8" O.D. polyethylene inside tubing. 1, 6, 12, 18, 24, 36, 48, and 60 in. lengths available. Ends in female luer connection. Length and ceramic type can be customized.  Complies with ASTM D4696-92(2000), Standard Guide for Pore-Liquid Sampling from the Vadose Zone.

0675D12X4K1-B0 Convenient kit for making a Tension Table (operation range 0 to 0.3 bar depending on the media used on to of the plate).
1920FK1 SET OF 8 FIELD 1920F1 KIT
0700G6 The 0700G6 Vacuum Control Manifold is designed for regulating and monitoring the negative pressure supplied to Ceramic Plates, Sandboxes and other types of vacuum extractors and instruments.
LAB09G3 The correct equipment for accurate measurement in the low tension range (0.05 to 0.3 bar).
LAB09G2 The correct equipment for accurate measurement in the low tension range (0.1 to 0.4 bar)
LAB09G1 The correct equipment for accurate measurement in the low tension range (0.4 to 0.8 bar).
LAB1425F1 TEMPE CELL LAB, 0-2 BAR PRESSURE MANIFOLD
LAB1250 Model Lab1250 is a precision extractor system designed so that the outflow section of the instrument is stable dimensional.
  •  per page